10 grass temperature sensor, 1 leaf wetness sensor specification, 2 leaf wetness - sensus channel configuration – Casella CEL Automatic weather station User Manual
Page 27: 1 grass temperature sensor specification

The installed device may be specified as optimised for either rain, frost
or dew. The rain sensing version incorporates a heater to dry the surface once
rain has ceased, and also to eliminate it’s sensitivity to the formation of dew.
The sensor will respond to a single 1 mm diameter droplet of distilled
water.
3.9.1
Leaf Wetness Sensor Specification
Part number:
187081B
Transducer:
Three element carbon electrode
Length:
150 mm
Supply voltage:
9 - 18 V DC
Power consumption:
5 mA Max
Output Calibration
Wet =1.5 V approximately
Dry = 0 V
Sensing area
15 x 30 mm
Operating temp.
-10°C to +55°C
Cable:
3 m cable supplied
3.9.2
Leaf Wetness - Sensus Channel Configuration
Description
Wetness
Units
None
Type
Analog
Information
Single ended
Gain x 1
No current source
Display Format
###.#
Polynomial
0, 1
Enabled
Yes
Logged
Yes
Minimum Limit
0
Maximum Limit
2.5
3.10 Grass Temperature Sensor
The grass minimum temperature
measurement is achieved by locating a
shielded thermometer at a fixed height
above the grass, supported on a small frame.
3.10.1 Grass Temperature Sensor Specification
Part number:
120650B
Sensor type:
Semi conductor current generator
02025
Figure 20: Grass temperature sensor
Page 27 of 34
Automatic Weather Station
Assembly & Commissioning Handbook