2 wind speed sensor, Standard sensors, 2 humidity sensor specification – Casella CEL Automatic weather station User Manual
Page 20: 1 wind speed sensor specification

3.1.2
Humidity Sensor Specification
Sensor type:
Capacitative
Measuring range:
0 - 100% RH
Calibrated accuracy:
±3% RH
Hysteresis:
±1%
Linearity:
±1.5% RH between 5% - 95% RH
Time constant:
<10 s between 10% and 90% RH
Operating temperature: -25° to +80°C
3.1.3
Air Temperature & Humidity - Sensus Channel
Configurations
Description
Air temperature
Humidity
Units
o
C
%RH
Type
Analog
Analog
Information
Single ended
Gain x 1
No current source
Single ended
Gain x 1
No current source
Display Format
+##.#
###.#
Polynomial
-40, 100
0, 100
Enabled
Yes
Yes
Logged
Yes
Yes
Minimum Limit
-40.0
0.0
Maximum Limit
+60
100.0
3.2
Wind Speed Sensor
The sensitive three cup anemometer is
mounted at one end of the cross-arm. The
rotational speed is monitored using an
infra-red light source, interrupter and optical
sensor that provides 20 pulses from 0 to 5 V
per revolution. This non-contacting design
can measure wind speeds up to 75 m/sec.
The instrument has an anodised
aluminium alloy outer case that offers a
durable, all-weather construction suitable for
installation in harsh environments.
An output from this sensor is led to
a terminal box on the sensor cross arm, from
where a single sensor cable is taken to the
7-pin socket on the bottom panel of the environmental case.
3.2.1
Wind Speed Sensor Specification
Part number:
178031C
Sensor type:
Three cup anemometer
Transducer:
Optical interrupter
Maximum wind speed:
75 m/s
Starting velocity:
Typically 0.3 m/s
Distance constant:
Typically 3.5 m/s
Time constant:
Typically <0.5 s
Resolution:
7.84 cm
Non-linearity:
<±0.6 %
Accuracy:
±0.3 m/s below 3 m/s
Standard Sensors
01057
Wind speed sensor
Page 20 of 34
Automatic Weather Station
Assembly & Commissioning Handbook