Fireplace installation, Fireplace insert installation, New wall construction – Dimplex DF2622SS User Manual
Page 9
9
26 ¾”
(679 mm)
23 ⅛”
(587 mm)
9”
(229 mm)
Figure 4
Dimensions without trim are 26
¼ inch (663 mm) wide x 22 ⅞
inch (580 mm) high x 8 ¾ inch
(222 mm) deep. The fireplace
does not require any additional
venting (Figure 3).
Fireplace Insert
Installation
Install the fireplace assembly
into the mantel (refer to mantel
assembly instructions).
!
NOTE 1: A 15 Amp, 120
Volt circuit is required. A
dedicated circuit is preferred
but not essential in all cases.
A dedicated circuit will be
required if after installation the
circuit breaker trips or fuse
blows on a regular basis when
the heater is operating.
Additional appliances
on the same circuit may
exceed the current rating of
the circuit breaker.
!
IMPORTANT: If not using
a Dimplex mantel, the
fireplace must be installed
in an enclosure with
the following
MINIMUM
dimensions (Figure 4).
New Wall Construction
select a suitable location that
1.
is not susceptible to moisture
and is away from drapes,
furniture and high traffic.
Place the fireplace in the
2.
desired location to see how it
will look in the room.
mark the desired location on
3.
the floor.
Use studs to frame an
4.
opening of 26 ¾ inch (679
mm) wide x 23 ⅛ inch (587
mm) high x 9 inch (229 mm)
deep.
Option #1: The power cord can
be run from behind the Trim
and along the wall to an outlet
near the fireplace.
Fireplace Installation