beautypg.com

5 setting the memory switches – BIXOLON SRP-350plusII User Manual

Page 13

background image

Rev. 1.05

- 13 -

SRP-350/352plusIIA&C

1-5 Setting the Memory Switches

This printer has “Memory Switch” set which is software switches. Memory Switch set has
“MSW1”, “MSW2”, “MSW8”, “MSW9” “Customize value”, “Serial communication condition”.
“Memory Switch setting utility” can change the Memory Switch set to ON or OFF as shown
in the table below. (default : all OFF)


NOTE
The Memory Switch is available to be changed by three methods.
- Memory Switch setting utility.
- Control from BXL/POS command.


Settings of the Memory Switch are stored in the NV memory : therefore, even if the printer
is turned off, the settings are maintained.



MSW1

Switch

Function

ON

OFF

1

Select Print Speed

Refer to following Table

2

3~8

Reserved

--

Fixed to OFF


180dpi

MSW 1-2

MSW 1-1

Print Density

Remark

OFF

OFF

Print Density 3

250mm/s

OFF

ON

Print Density 2

230mm/s

ON

OFF

Print Density 1

200mm/s


203dpi

MSW 1-2

MSW 1-1

Print Density

Remark

OFF

OFF

Print Density 3

230mm/s

OFF

ON

Print Density 2

200mm/s

ON

OFF

Print Density 1

180mm/s


MSW2

Switch

Function

ON

OFF

1

Specification for

Destination

Double byte Country

Single byte Country

2

Reserved

--

Fixed to OFF

3

Code Page Selection

Refer to following Table

4
5
6
7
8

This manual is related to the following products: