Ip commands – Atlona AT UHD SW 52ED User Manual
Page 16

16
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Command
Feedback
Description
IPCFG
IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port : x
Displays IP address configuration
IPQuit
IPQuit
Logs out of TCP/IP Connection
IPAddUser X Y
Ex. IPAddUser Atlona 1234
TCP/IP user was added
Adds a user for TCP/IP control
X= user and Y= Password
IPAddUser
username password
username password
username password
Displays a list of users and passwords
IPDelUser X
TCP/IP user was deleted
Delete a user from TCP/IP X= username
IPDHCP X
IPDHCP X
Turns HDCP on or off X= on, off, sta
IPStatic X Y Z
Ex. IPStatic 192.168.1.1
255.255.255.0
192.168.1.200
IPStatic X Y Z
Ex. IPStatic 192.168.1.1
255.255.255.0
192.168.1.200
Sets static IP address
IPStatic Address(X) Netmask(Y) Gateway(Z)
IPPort X
IPPort X
Set the TCP/IP Port
IPLogin X
Ex. IPLogin off
IPLogin X
Ex. IPLogin off
Enables IP Login
X= on, off, sta
Broadcast X
Ex. Broadcast on
Broadcast X
Ex. Broadcast on
Sets broadcast mode on or off
X= on, off, sta
IPTimeout XX
Ex. IPTimeout 300
IPTimeout XX
Ex. IPTimeout300
Determines amount of seconds of inactivity before TCP/IP
disconnects
Each command or feedback is terminated with a carriage return.
Note: If the command fails or is incorrect the feedback is “Command FAILED”
IP Commands
Zone output baud commands
(for display control)
RS232para1[baudrate,data-length,parity,stop-bit]
Example: To change the output baud rate to 19200 use RS232para1[19200,8,0,1]
RS232zone1[command]
Once the switcher and zone output have been set up for the best communication, commands can be sent
to control the display. The commands will come from the user manual of the display or projector. The com-
mands and any carriage returns/line feeds in the commands will need to be placed in the bracket.
Example: To turn the display or projector on if the command is PWRON carriage return, use the command:
RS232zone1[PWRON carriage return]
Note: Use this command if the connected control system does not output 115200
Note: Use this command if the connected display uses a different baud rate
Baud Rate
Default baud rate to control the switcher is 115200 and default baud rate to control the display or projector
is 9600.
Note: For the display’s actual baud rate, refer to the owner’s manual
To change the baud rate of the switcher (for switcher control) or the zone output (for display/projector
control), the commands below will be needed
Switcher baud command
CSpara[baudrate,data-length,parity,stop-bit]
(data-length, parity, and stop-bit for switcher must be 8,0,1)
Example: To change the baud rate to 38400 use CSpara[38400,8,0,1]