Step 2 - canopen setup, Step 3 - configuration, Stac6-c quick setup guide – Applied Motion STAC6-C User Manual
Page 2: 0046 a, Bit rate table

920-0046 A
STAC6-C Quick Setup Guide
Step 2 - CANOpen Setup
Connect to CAN network.
▪
Applied Motion Products STAC6-C drives use a four-pin
spring connector, that conforms to the DR303 specification.
The connector should be wired in a daisy-chain configuration
with a 120 Ohm resistor used to terminate each end.
Switch Setting
Resultant Bit Rate
0
1 Mbps
1
800kbps
2
500 kbps
3
250 kbps
4
125 kbps
5
50 kbps
6
20 kbps
7
12.5 kbps
8
n/a
9
n/a
Bit Rate Table
Connect the drive to your PC using the RS-232 programming cable.
▪
▪
Launch the software by clicking Start/Programs/Applied Motion Products/STAC Configurator
▪
Step 3 - Configuration
▪
Apply power to the drive.
▪
Use the STAC Configurator™ to set up the motor current, load iner-
tia, limit switches, encoder functionality (if applicable) and Node ID.
The
▪
STAC Configurator™ includes a self test option (under the Drive menu)
to verify that the STAC6-C and motor are correctly wired and configured.
When configuration is complete, exit
▪
STAC Configurator™.
The drive will automatically switch to CANOpen Mode.
▪
Customer Support (800)525-1609 or visit us online at www
404 Westridge Dr.
Watsonville, CA 95076
Tel: 800-525-1609
Fax: 831-761 -6544
5
5
4
4
3
3
2
2
1
1
D
D
C
C
B
B
A
A
CAN_GND
CAN_SHLD
CA
N_
H
CA
N_
SH
LD
CA
N_
L
CA
N_
G
ND
CAN_L
CAN_H
CA
N_
H
CA
N_
SH
LD
CA
N_
L
CA
N_
G
ND
Title
Size
Document Number
Rev
Date:
Sheet
of
N/A
A
CANopen Network Cable for Applied Motion Drives and Kvaser LeafLight HS
A
1
1
Monday, November 24, 2008
Title
Size
Document Number
Rev
Date:
Sheet
of
N/A
A
CANopen Network Cable for Applied Motion Drives and Kvaser LeafLight HS
A
1
1
Monday, November 24, 2008
Title
Size
Document Number
Rev
Date:
Sheet
of
N/A
A
CANopen Network Cable for Applied Motion Drives and Kvaser LeafLight HS
A
1
1
Monday, November 24, 2008
n*
R termination:
Network must be terminated
at each end with a 120 ohm
resistor.
n:
Cable may be made with up to 254
drive connectors. Termination is
only required at each end.
CAN_BUS
DSUB9 Female
DSUB9 Female
1
2
3
4
5
6
7
8
9
.1" Spacing Spring Plug
.1" Spacing Spring Plug
4 3 2 1
R termination*
120 ohm nominal
R termination*
120 ohm nominal
.1" Spacing Spring Plug
.1" Spacing Spring Plug
4 3 2 1
R termination*
120 ohm nominal
R termination*
120 ohm nominal
Set BitRate, Node ID
▪
CANOpen Bitrate - AMP CANOpen drives have three set-
tings, one for Bit Rate and two for Node ID. The Bit Rate
is configured using an eight-position switch. See Bit Rate
table for the Bit Rate settings. The Node ID is configured
using a sixteen position switch to set up the lower four bits
of the Node ID. The upper three bits of the Node ID are set
using the STAC Configurator™. Valid ranges for the Node
ID are 0x01 through 0x7F. Node ID 0x00 is reserved in ac-
cordance with the DS301 specification.
Note: The Node ID and Bit Rate are captured only after a
power cycle, or after a network reset command has been
sent. Changing the switches while the drive is powered on
will NOT change the Node ID or Bit Rate until one of these
conditions has been met.
GND
CAN_L
SHLD
CAN_H