beautypg.com

Dimplex Duo400i User Manual

Dimensions, Important safety information, Ab c

background image

Dimplex DuoHeat Radiator
Models: Duo300i, Duo400i and Duo500i

Operating Instructions

85601 Issue 5

Dimensions

(millimetres)

Models

Specification

Rated Charge

300i

1.3kW / 0.28kW

9.1kWh

400i

1.95kW / 0.34kW

13.65kWh

500i

2.6kW / 0.39kW

18.2kWh

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

IMPORTANT SAFETY INFORMATION

WARNING - THE SURFACE OF THIS RADIATOR CAN BE HOT.
The surface temperatures of this radiator are within the requirements of EN60-335 the European Standard covering the safety

requirements of electric heating appliances, and momentary contact with any part of the radiator should not cause injury.
However, in order to be effective, radiators of any type do get hot, especially around the air outlet grille.
Therefore, if aged or infirm persons, or young children, are likely to be left unsupervised in the vicinity of a radiator
precautions should be taken to ensure that prolonged contact with the radiator cannot occur.
We recommend that a

guard is fitted around the radiator, as is normal with some types of heating appliances in similar circumstances. If you require
further information on these guards, please contact Dimplex Customer Services on 0870 7270 101.
WARNING - IN ORDER TO AVOID OVERHEATING, DO NOT COVER THE SURFACES OF THE RADIATOR AND DO

NOT OBSTRUCT AIR OUTLET GRILLES Surfaces of the radiator should not be covered or obstructed as this can cause
excessive temperatures that can be hazardous and may cause safety cut-outs to operate. For example, do not put clothes,

fabrics or any combustible materials on the radiator or allow curtains to come within 75mm (3”) of the top and ends of the
radiator. Do not allow furniture to be pushed up against the radiator, a minimum clearance of 150mm is critical for safety,
however to ensure radiator performance is not affected a clearance of 250mm is recommended.
DO NOT PLACE OBJECTS IN CONTACT WITH THE RADIATOR

WARNING – The radiator must not be located below a socket outlet.
PLEASE NOTE: THIS RADIATOR IS HEAVY AND MUST BE SECURELY FIXED TO A SOUND WALL. No attempt

should be made to move the radiator without first seeking specialist advice. If you are not happy that the radiator has

been securely fixed, please inform your installer.
UNDER NO CIRCUMSTANCES SHOULD YOU ATTEMPT TO MOVE THE RADIATOR OR LOOSEN WALL FIXINGS
WITHOUT FIRST REMOVING ALL ENERGY RETENTION CELLS FROM THE RADIATOR.

DO NOT SIT OR STAND ON THE RADIATOR.
DO NOT SPILL LIQUIDS ONTO THE APPLIANCE. IF YOU DO, SWITCH THE RADIATOR OFF AND GET A QUALIFIED

ELECTRICIAN TO CHECK IT.

DO NOT POKE OBJECTS THROUGH THE GRILLE.
DO NOT PLACE OBJECTS IN THE SPACE BEHIND THE RADIATOR.
DO NOT USE POLISHES ON THE RADIATOR OR ON FURNITURE NEAR TO IT. The hot interior of the radiator can

produce paraffin smells from polish vapours which may last for a number of hours.

• In case of breakdown or other failure, switch off the radiator at both wall switches and contact your supplier or Dimplex Customer

Services. Always ensure that the radiator is switched off at the wall and fuse is removed before any repair is carried out.

IMPORTANT - Due to the newness of the materials the radiator will produce a slight smell for the first few days of operation.

ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS OR PERSONS WITH RESPIRATORY
COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE RADIATOR DURING THE FIRST 48 HOURS OF
THE COMMISSIONING PERIOD. Running the radiator at maximum temperature for the first few days will help to dispel
any smells more quickly.

Wall, Curtains or Furniture

Curtains

Shelf or Overhang

Furniture
or other
obstruction

110mm

150mm
min.

250mm
min.

75mm
min.

A

B

C

75mm
min.

Radiator Positioning A minimum clearance of 150mm to the
front of the radiator is essential for safety, however to enable the
radiator to attain its maximum performance ensure that any
furniture or other obstruction is not placed closer than 250mm.

Model

Height

A

Width

B

Depth

C

Duo300i

712mm

600mm

130mm +10mm

Duo400i

712mm

830mm

130mm +10mm

Duo500i

712mm

1060mm

130mm +10mm