Operating Instructions and Parts Manual
1P579F
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by obeying all Safety Information. Failure to comply with Instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Dayton
™
Marine Utility Pump
Description
Dayton marine utility pump is designed for general commercial and
industrial applications. Unit is designed for water, but is not submersible.
For use transferring liquids, emptying or filling tanks, sinks or bowls. The
pump can be used to pump bilge water, but the pump must not be
located in the bilge area. Self-priming to 7 ft. if the impeller is initially
wet (primed). Intermittent duty. Carrying handle included.
NOTE: Unit is NOT RECOMMENDED for use with soap detergents, gasoline,
waste oil, fuel oil, flammable, explosive or combustible liquids or other
fluids not compatible with pump component materials. Do not use unit
in enclosed areas. Intermittent duty only (15 minutes per hour).
Unpacking
When unpacking the unit, inspect carefully for any damage that may
have occurred during transit. Check for loose, missing, or damaged parts.
Two extra impellers and gaskets are included with pump.
Specifications
Power supply required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115V, 60Hz
Fuse requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Amps
Maximum liquid temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140°F
Minimum liquid temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°F
Thermal protection . . . . . . . . . . . . . . . . . . . . . . . . . . . .Automatic Resetting
Motor amps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.60 Amps
Duty Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intermittent