3
FORM NO. L-20355-B-0200
0.78
[20]
DETECTOR DARK
LEFT
RIGHT
PROJECTOR ON
POWER
ON
10.62
(270mm)
9.04
(157 mm)
Cutout
6.06
(154 mm)
6.18
(157 mm)
4.96
(126 mm)
4.33
(110 mm)
+
+
+
+
10.15
(258mm)
Cutout
9.72
(247 mm)
5.98
(152 mm)
.24
[6mm]
.47
[12mm]
FIGURE 4 AS10-D Amplifier Cutout Dimensions
1.
Mount the AS10-D Amplifier on either a flat surface or in a panel. To mount the AS10-D Amplifier in a panel, position the
mounting brackets to the front of the amplifier. To mount the AS10-D Amplifier on a flat surface, position the mounting
brackets to the rear of the amplifier (default).
CAUTION
Mount the AS10-D Amplifier in a dry, dust free, shock and vibration free area with an ambient
temperature greater than 32
o
F [0
o
C] but less than 122
o
F [50
o
C].
Flat Surface Mount
Panel Mount
FIGURE 3 Mounting the AS10-D Amplifier
AMPLIFIER INSTALLATION