TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

SOLUTION

Failure to engage.

Air not getting to the STC.

Check for a control valve malfunction

or low air pressure.

Failure to disengage.

Unexhausted air.

Check for a control valve malfunction.

Friction Facing squeal or

chatter.

Air pressure too high.

Reduce the air pressure.

Wrong Friction Facings for the application.

Replace the Friction Facing with

correct facing for the application.

Wobble or vibration.

Shaft misalignment.

Inspect the shaft and realign it if

necessary.