Air connections – Nexen FMCB-7-38 801613 User Manual
Page 7

FORM NO. L-20179-H-1209
7
3/2 (3 Way)
4/2 (4 Way)
5/2 (4 Way)
5/2 (5 Way)
aIr COnneCTIOnS
nOTe
For quick response, nexen recommends a quick exhaust
valve and short air lines between the Control Valves and
the product. align the air inlet ports to a down position
to allow condensation to drain out of the air chambers
of the product.
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
Air Pressure (Gage) Limits
6.9 Bar (100 PSI) Absolute Max.
0 Bar (0 PSI) Absolute Min.
The following are common air supply schemes used with
this product. These are examples and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.
- FMCB-8-42 801619 FMCB-8-38 801616 FMCB-130-19 801400 FMCB-130-24 801403 FMCB-7-28 801610 FM 7-28 Input Unit 801627 FM 7-28 Input Unit 801575 FM 8-38 Input Unit 801629 FM 8-38 Input Unit 801601 FM 7-38 Input Unit 801628 FM 7-38 Input Unit 801608 FM 8-42 Input Unit 801630 FM 8-42 Input Unit 801602 FMCBE-875 801428 FMCBE-7-38 801638 FMCBE-7-28 801637 FMCBE-8-38 801639 FMCBE-8-42 801640