FORM NO. L-20124-G-0210

AIR CONNECTIONS

The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must
be designed following EN983 guidelines.

All Nexen pneumatically actuated devices require clean,
dry air that meets or exceeds ISO 8573.1:2001 Class
4.4.3 to quality.

CAUTION

Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.

NOTE

For quick response, Nexen recommends a quick

exhaust valve and short air lines between the

Control Valves and the unit. Align the air inlet

ports to a down position to allow condensation

to drain out of the air chambers of the product.

OPERATION

CAUTION

CAUTION

Never exceed life of facing material. Facing
life depends on the volume of material and
the total energy over the life of the unit.
Expected life (in hrs) can be found by:
Time=

Volume

/

(Power • Wear Rate)

WARNING

Ensure proper guarding of the product is
used. Nexen recommends the machine
builder design guarding in compliance
with OSHA 29 CFR 1910 “Occupa-
tional Safety and Health Hazards.”

TABLE 3 Maximum Operating Speeds

Model

RPM

MB450S

3600

MB600S

3600

MB800S

1800

WARNING

The temperature limits for this product line
are 4.5º - 104º C (40º-220º F).

Never exceed maximum operating speeds
listed for your product (See Table 3).