beautypg.com

Troubleshooting – Nexen S-450 827801 User Manual

Page 8

background image

FORM NO. L-20087-P-1112

8

SYMPTOM

PROBABLE CAUSE

SOLUTION

Failure to engage

Air not being exhausted due to a control
valve malfunction

Replace the control valve.

Internal contamination or corrosion

Align the exhaust port to the six o'clock down

position to allow condensation to drain out of

the exhaust port.

Failure to

disengage

Broken Compression Springs

Replace the Compression Springs.

Low or lack of air pressure

Check for control valve malfunction and
replace it if necessary.

Check for air leaks in the air lines and around

the O-rings Seals. Replace the air lines or O-

ring Seals if necessary.

Internal contamination or corrosion

Align the exhaust port to the six o'clock down

position to allow condensation to drain out of

the exhaust port.

Loss of torque

Worn or dirty Friction Facings

Replace the Friction Facings.

TROUBLESHOOTING

FIGURE 4

Friction

Facing

Piston

Plate

Shoulder

Bolt

Compression

Spring

Ball

Bearing

O-ring

Seals

Air

Chamber

Piston

Friction

Disc Hub