USING THE CLIENT SOFTWARE

Digimerge Dialup Video Server User’s Guide

26


There are two kinds of sensor state (see State field in Figure 9):

Normally Open - the non-signaled state of sensor input – HI, when sensor input is not

connected or connected to digital HI level

Normally Closed - the non-signaled state of sensor input – LO, when sensor input is tied

to the ground or digital LO level.

By pressing the Restore to default button you can assign all alarms as Normally Open. A green
sensor icon in the State field means signaled state - alarm. After deciding all sensor states, you
can press the Remember current state as normal button for saving your configuration and
now DVS will generate an alarm signal when the sensor is toggled.

Figure 9 Configuring the alarm sensors

The Enable/Disable sensors control will allow you to activate or deactivate each sensor. You
can specify the name of sensor in the edit box. The Camera for sensor field allows you to
choose the camera and assign it to a sensor alarm. One of four cameras may be connected to
each sensor. If we have a sensor set on a door, and one of the cameras is directed at the door,
you should specify the camera number in the Camera for sensor field. When this sensor
toggles to a signaled state, DVS will capture a defined number of snapshots with a defined
delay, in seconds (Num Images & Delay) from the defined camera. When 1 image from the
camera is specified, a delay will occur before the image is captured.