beautypg.com

Fireplace installation – Desa (V)T36ENA User Manual

Page 19

background image

www.desatech.com

111251-01E

19

FIREPLACE

INSTALLATION

Continued

Figure 27 - Location of Wiring Diagram

Decal (Model May Vary from Illustration)

Wiring Diagram
Decal 12" in Front
of Burner

9. Check to make sure power cord is completely

clear of blower wheel and there are no other

foreign objects in blower wheel. Turn blower

on and check for operation. Turn blower off

by turning knob fully counterclockwise before

continuing.

10. Peel off backing paper and stick supplied wiring

diagram decal on firebox bottom approximately

12" in front of blower (see Figure 27).

Model BKT Installation
Note

: When installing BKT thermostatically-

controlled blower, you must first secure thermal

switch bracket to blower if it has not already been

factory installed.

1. Place green ground wire with ring terminal be-

tween bottom hole on thermal switch bracket

and top ear hole on blower assembly. Insert

phillips screw into all three pieces and tighten

securely (see Figure 28).

2. Connect wire harness and power cord ter-

minals. Connect blue jumper wire to blower

motor terminal and right side terminal of

thermal switch. Connect black wire to left

side of thermal switch and white wire to other

remaining blower motor terminal.

Note:

Power cord outer insulation sleeve may have

to be stripped slightly to allow enough wire length

to reach and make all connections. DO NOT trim

excessive length away. Just enable enough to make

all connections securely.

3. Place blower against lower rear wall of firebox

outer wrapper with exhaust port directed up-

ward and thermodisc positioned up near fire-

place bottom. Thermodisc must be oriented near

fireplace bottom as shown in Figure 29 in order

to sense temperature and properly operate.

Blower will be held in position against back

wall by magnets incorporated onto blower

housing (see Figure 28).

4. Be certain that all wire terminals are securely

attached to terminals on blower motor and

thermal switch, and that screw for thermodisc

bracket and green ground wire is tight.

5. Mount speed control box against mounting

plate provided in lower fireplace cavity by

placing plastic control shaft forward through

round hole (see Figure 26, page 18).

6. While supporting speed control, secure control

shaft with lock nut by pushing and turning

lock nut with pliers clockwise until it is tight

against mounting plate. Place control knob

provided on shaft (see Figure 26, page 18).

7. Check to make sure power cord is completely

clear of blower wheel and that no other foreign

objects are in blower wheel. Also double

check all wire leads and make sure wire rout-

ing is not pinched or in a precarious position.

Correct accordingly.

8. Turn on power to duplex outlet if previously

turned off per warning in column 1, page 18.

9. Plug in blower power cord to duplex outlet.

10. Blower will only run when speed control knob is

in ON position and thermal switch senses tem-

perature after fireplace begins to heat up. Blower

speed can be adjusted by rotating control knob.

To turn off, turn knob fully counterclockwise

until it clicks off. If blower is ON and has been

running with fireplace operating, blower will

continue to run for a short time after fireplace

has been turned off. As thermal switch cools

down, blower shuts down automatically.

Figure 28 - Blower Model BKT

Black
Wire

Phillips
Screw

Blue Wire

Ring
Terminal on
Green Wire

White Wire

Thermal
Switch

Thermal

Switch

Bracket

Power Cord

Air Flow
Direction

Magnetic
Strips

Side View Firebox Bottom

Route BKT Blower
Through This Area

Thermodisc

Air Flow
Direction Magnets

Blower