Thermal considerations, Thermal curves, Thermal testing setup – Delta Electronics S48SA User Manual

Page 9: Thermal derating

background image

DS_S48SA05006_06022006

9

THERMAL CONSIDERATIONS


Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.

Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.


Thermal Testing Setup


Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.

The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module or a heat sink is
6.35mm (0.25”).

Thermal Derating


Heat can be removed by increasing airflow over the
module. The module’s maximum hot spot temperature is
115℃. To enhance system reliability, the power module
should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.

Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)

10 (0.4”)

MODULE

AIR FLOW

50.8 (2.0”)

FACING PWB

PWB

AIR VELOCITY
AND AMBIENT

TEMPERATURE

MEASURED BELOW

THE MODULE

Figure 17:

Wind Tunnel Test Setup


THERMAL CURVES

S48SA05006(Standard) Output Current vs. Ambient Temperature and Air Velocity

@ Vin = 48V (Either Orienation)

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

65

70

75

80

85

90

95

100

105

Ambient Temperature (℃)

Output Current(A)

Natural

Convection

100LFM

200LFM

300LFM

400LFM

500LFM

600LFM

Figure 19:

Output current vs. ambient temperature and air velocity

@V

in

=

48V











Fiture 18:

Hot spot temperature measured point

The allowed maximum hot spot temperature is defined at 115