Vortech Alpha H3 Hummer - 2008 User Manual
Page 21

P/N: 4GN020-015
©2008 Vortech Engineering, LLC
All Rights Reserved, Intl. Copr. Secured
20OCT08 v2.0 08HummrH3(4GNv1.0)
15
7. CHARGE COOLER INSTALLATION, cont’d
Fig. 7-g
R.
Secure all hose connections at this time
using the supplied nylon ratchet clamps.
Make sure that all hoses are routed and
secured away from hot or moving parts.
S.
Using the supplied butt connector, attach the
supplied length of wire to the poitive (green)
wire on the water pump. Route the wire to the
power distribution box (PDB) located on the
driver side. Trim the wire so that it just
reached the PDB. Connect the supplied fuse
holder to the end of the wire. Attach the
trimmed piece of wire to the opposite side of
the fuse holder. Locate the fuel pump relay.
Using the mini ATC fuse tap and the supplied
femal spayed connector attach the wire to
terminal #87 on the relay. (see Fig. 7-g)
T.
Attach the supplied ring terminal to the water
pump ground wire. Secure the ground wire to
the inner fender using the supplied M8 fas-
tener.
U.
Fill the CAC coolant using a 25%/75% anti-
freeze/water mix. Fill through the surge tank
fill port located on the CAC.