8. RECALLING DATA

1. Press the Recall Key once

'Addr' will be displayed on the top line along with a location number from
0 to 49 flashing on the screen. Select the required address location that
you wish to save the data to by pressing the Up and Down Arrow Keys

2. Press the Scroll/Enter Key once

The Time & Date of the Saved Data from the selected address location will
be displayed flashing on the screen.
The rest of the Saved Data at this address location can be reviewed by
pressing the Up and Down Arrow Keys

4. Press the Scroll/Enter Key once when you are finished reviewing the data.

'End' will be displayed with 'YES' flashing

5. Press the Scroll/Enter Key once to EXIT

or

6. Press the Up or Down Arrow Keys

'End' will be displayed with 'no' flashing

7. Press the Scroll/Enter Key once to CHOOSE another address location to

review and repeat steps 2 to 5

7. SAVING DATA

During testing, data can be stored for later retrieval by following these steps:

1. Press the Store Key once

'Addr' will be displayed on the top line along with a location number from 0 to
49 flashing on the screen. Select the required address location that you wish
to save the data to by pressing the Up and Down Arrow Keys

2. Press the Scroll/Enter Key once

The location number which you have chosen will stop flashing and after about
3 seconds the instrument will return to the screen/function you were previous-
ly on.

You have just successfully stored a set of readings which can be either
reviewed on screen (see 8) or sent to the IR printer (see 9)

When data is saved, all data previously in the address will be overwritten.When
saving pressure/draft readings, select an address different from the one used
to save combustion readings.