Application Notes

When measuring DC Voltage of a
battery, the most accurate reading can
be attained by testing the battery
under load. To accomplish this, follow
steps 1 through 4 shown on page 15
and the following (with the battery in
holder and device turned on):

• Connect the red test lead from the

meter to the positive (+) terminal
of the battery.

• Connect the black test lead to the

negative (-) terminal of the battery.

• Reconnect power to the circuit and

read the voltage on the 183.

3.

Step by Step Procedures:

a.

Measuring DC Volts

CAUTION!
Do not attempt to make a voltage measurement if
a test lead is plugged in the A or mA input jack.
Instrument damage and/or personal injury may
result.

WARNING!

Do not attempt to make a voltage measurement of
more than 1000V or of a voltage level that is
unknown.

Instrument set-up:

FUNCTION

BLACK

RED

MINIMUM

MAXIMUM

TEST LEAD

TEST LEAD

READING

READING

mV

COM

V

Ω Hz

0.1mV

400.0mV

V

COM

V

Ω Hz

0.001V

1000V

Measurement Procedure:

1.

Disconnect power to circuit to be measured.

2.

Plug black test lead into the COM input jack.

3

Plug red test lead into the V input jack.

4.

Set rotary switch to either the mV or V range,
depending on the voltage to be measured.

5.

Connect test leads to circuit to be measured.

6.

Reconnect power to circuit to be measured.

7.

Read the voltage on the 183.