beautypg.com

Test Products International 183 User Manual

Page 10

background image

9

8

3.

Specifications

IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2

a. DCV

Range

Resolution Accuracy

Impedance

400mV

0.1mV

±0.3% of reading,

10M

4V

0.001V

±2 digits

40V

0.01V

400V

0.1V

1000V

1V

b1. ACV (45Hz to 450Hz)

Range

Resolution Accuracy

Impedance

4V

0.001V

±0.75% of reading,

10M

40V

0.01V

±5 digits

400V

0.1V

750V

1V

b2. ACV (450Hz to 5kHz)

Range

Resolution Accuracy

Impedance

4V

0.001V

unspecified

10M

40V

0.01V

±2% of reading,

400V

0.1V

±5 digits

750V

1V

b3. ACV (5kHz to 20kHz)

Range

Resolution Accuracy

Impedance

4V

0.001V

unspecified

10M

40V

0.01V

±2.5% of reading,

400V

0.1V

±5 digits

750V

1V

unspecified

2.

Product Applications

Perform the following tests and/or measurements
with the TPI 183 and the appropriate function:

HVAC/R

DCmV

• Thermocouples in furnaces or gas

applications.

ACA

• Heat anticipator current in thermostats.

ACV

• Line voltage.

ACV or DCV • Control circuit voltage.
DCµA

• Flame safeguard control current.

OHMS

• Heating element resistance (continuity).

OHMS

• Compressor winding resistance.

OHMS

• Contactor and relay coil resistance.

OHMS

• Continuity of wiring.

CAP

• Motor start and run capacitance.

Hz/FREQ

• Frequency on controls and line voltage.

REC

• Record min/max voltage of controls and line

voltages.

DCmV

• Temperature with optional temperature

adapter (A310).

ALL

• Bar graph to indicate rapid fluctuations in

measurements.

ELECTRICAL

ACV

• Measure line voltage.

OHMS

• Continuity of circuit breakers.

Hz/FREQ

• Frequency of line and control voltage.

DCV

• Voltage of direct drive DC motors.

ELECTRONIC

ACV

• Measure power supply voltage.

OHMS

• Continuity of circuit breakers.

REL%

• Match components

COMP

• Compare readings in circuits or components

Hz/FREQ

• Frequency of line and control voltage.

UL 3111-1