Test Products International 183 User Manual
Page 10
![background image](/manuals/742567/10/background.png)
9
8
3.
Specifications
IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2
a. DCV
Range
Resolution Accuracy
Impedance
400mV
0.1mV
±0.3% of reading,
10M
Ω
4V
0.001V
±2 digits
40V
0.01V
400V
0.1V
1000V
1V
b1. ACV (45Hz to 450Hz)
Range
Resolution Accuracy
Impedance
4V
0.001V
±0.75% of reading,
10M
Ω
40V
0.01V
±5 digits
400V
0.1V
750V
1V
b2. ACV (450Hz to 5kHz)
Range
Resolution Accuracy
Impedance
4V
0.001V
unspecified
10M
Ω
40V
0.01V
±2% of reading,
400V
0.1V
±5 digits
750V
1V
b3. ACV (5kHz to 20kHz)
Range
Resolution Accuracy
Impedance
4V
0.001V
unspecified
10M
Ω
40V
0.01V
±2.5% of reading,
400V
0.1V
±5 digits
750V
1V
unspecified
2.
Product Applications
Perform the following tests and/or measurements
with the TPI 183 and the appropriate function:
HVAC/R
DCmV
• Thermocouples in furnaces or gas
applications.
ACA
• Heat anticipator current in thermostats.
ACV
• Line voltage.
ACV or DCV • Control circuit voltage.
DCµA
• Flame safeguard control current.
OHMS
• Heating element resistance (continuity).
OHMS
• Compressor winding resistance.
OHMS
• Contactor and relay coil resistance.
OHMS
• Continuity of wiring.
CAP
• Motor start and run capacitance.
Hz/FREQ
• Frequency on controls and line voltage.
REC
• Record min/max voltage of controls and line
voltages.
DCmV
• Temperature with optional temperature
adapter (A310).
ALL
• Bar graph to indicate rapid fluctuations in
measurements.
ELECTRICAL
ACV
• Measure line voltage.
OHMS
• Continuity of circuit breakers.
Hz/FREQ
• Frequency of line and control voltage.
DCV
• Voltage of direct drive DC motors.
ELECTRONIC
ACV
• Measure power supply voltage.
OHMS
• Continuity of circuit breakers.
REL%
• Match components
COMP
• Compare readings in circuits or components
Hz/FREQ
• Frequency of line and control voltage.