beautypg.com

D. measurement techniques – Test Products International 163 User Manual

Page 10

background image

10

11

mA

Function for measuring milliamps (mA) AC.
1 milliamp = 0.001Amp

10A

Function for measuring AC Amps (A).

Function for using audible Continuity Buzzer.

Function for measuring Ohms (resistance)
and testing Diodes.

OFF (O) Manually turns the 163 off.

1.

Controls and Functions: (cont.)

Input Jacks

Fuse Protection

mA: 0.5Amp/600VAC A: 10Amp/600VAC

Display Type

3260 Count,with 34 segment bargraph
and low battery indication.

Operating Temp.

-0° to 40°C (32° to 104°F)

Storage Temp.

-10° to 50°C (14° to 122°F)

Relative Humidity

0% to 80%

Power Supply

2 each 1.5 Volt “AA” Batteries

Battery Life

200 hrs. Typical

Size (H x L x W)

33mm x 86mm x 187mm (1.3in x 3.4in x 7.4in)

Weight

340g (12oz)

D. MEASUREMENT TECHNIQUES

1.

Controls and Functions:

Push Buttons

RANGE

Activates manual ranging. Hold in for 3 sec-
onds to return to autorange. Also selects
between continuity buzzer and diode test.

DATA-H Holds the reading on the display until the

button is pushed a second time.

Rotary Switch

OFF(O) Manually turns the 163 off.

10A

Function for measuring DC Amps (A).

mA

Function for measuring milliamps (mA) DC.
1 milliamp = 0.001 Amp

µA

Function for measuring microamps (µA) DC.
1 microamp = 0.000001Amp

V

Function for measuring DC Volts.

V

Function for measuring AC Volts.

µA

Function for measuring microamps (µA) AC.
1 microamp = 0.000001Amp

mA

Function for measuring milliamps (mA) AC.