Saf-te board scsi id set-up – StorCase Technology S10A100 User Manual
Page 12
StorCase Technology, Inc.
SAFTEmon Users Guide - Rev. E00
12
S10A100
SAF-TE Board SCSI ID Set-Up
(The following information only applies to the 9 & 14-Bay 4U InfoStations)
NOTES:
SAF-TE board SCSI ID is factory set to SCSI ID15.
The SAF-TE SCSI ID can be changed anytime. It will only take effect after a
system power up however.
Press CANCEL at anytime to exit the menu system and return to the Default
Display. The menu system will automatically cancel after 15 seconds of User
inactivity.
The following steps show how to change the SAF-TE board SCSI ID via the InfoStation UI
Module. Refer to the InfoStation User's Guide (specifically, section "InfoStation User
Interface") for further information.
1.
Press ENTER at the Default Display so that
display = Status.
2.
Press DOWN until display = SAFT Cfg.
3.
Press ENTER so that display = SCSI ID.
4.
Press ENTER again so that display = SAFT1:xx.
This is the current SAF-TE SCSI ID.
5.
Press UP or DOWN to change the SAF-TE SCSI
ID.
6.
Press ENTER to accept the change.