InfoStation 12-bay JBOD User's Guide - Rev. A00

StorCase Technology, Inc.

JBOD Controller Configuration

25

Table 4: Terminal Program Communications Parameters

Set the communications parameters as follows:

Figure 10: Monitor Utility Screen

To start the Monitor Utility from the remote terminal (or terminal emulation program), press

Ctrl-D. This will invoke the Monitor Utility (Figure 10).
At the top of the screen is the Model Number and Firmware version of the JBOD Controller.

At the left, is the "LCD Display" window. The information displayed here also appears on the

front LCD display. Below is the "Menu" window with the Main Menu options. To the right is

the "OUTPUT" window that shows more detailed information about the JBOD Controller. At

the bottom of the screen is the navigation legend.

Setting

Value

Baud Rate

Data Bits

Stop Bits

Parity

Flow Control

2400, 4800, 9600, 14400, 19200,

28800, 38400, 57600, 115200

7, 8

1, 2

None, Odd, Even

Software Flow Control (XON/XOFF)

Default Value

115200

8

1

None

Enabled