Installing the receiving frame – StorCase Technology DE90i-A100 User Manual

Page 15

background image

8

Installation

StorCase Technology, Inc.

DE90i-A100 User's Guide - Rev. B02

Installing the Receiving Frame

The drive should be installed into the carrier before installing the receiving frame into the

mounting bay of a computer or expansion chassis.

NOTE:

Use a #2 Phillips screwdriver during this procedure.

1.

Turn OFF power to the computer.

2.

Open the computer system according to the manufacturer’s instructions. If

necessary, temporarily remove any expansion boards that may make installation

difficult.

3.

Select the Master/Slave configuration on the rear of the receiving frame by placing

a jumper on the appropriate (J5) pins (Figure 7).

NOTE: Invalid jumper configuration of J5 will cause all LEDs (A, B, C) to blink

(refer to Table 1).

Figure 7: Master/Slave Configuration Jumper J5

4.

With the drive carrier locked in place inside the receiving frame, install the

DE90i-A100 into the 5.25" drive opening in the computer or expansion chassis. Use

the appropriate guides to position the Data Express, and fasten it into place with

the four (4) #6-32 Phillips screws provided. Figure 8 illustrates the location of the

mounting holes. Mounting holes are provided on each side and the bottom of the

receiving frame to accommodate a variety of mounting configurations. Use the

mounting holes which best suit the computer or expansion chassis configuration.

NOTE: Bottom mounting holes require self-tapping screws (not provided).

5.

Adjust the front of the receiving frame so that the carrier slides freely in and out

on the receiving frame guides. The position of adjoining peripheral units may require

adjustment.