Receiving frame front panel – StorCase Technology DE90i-A100 User Manual

Page 11

background image

4

Introduction

StorCase Technology, Inc.

DE90i-A100 User's Guide - Rev. B02

Table 1: Receiving Frame Front Panel Indicator Conditions

Figure 3: Receiving Frame Front Panel

CONDITION

LED A

LED B

LED C

Carrier removed from receiving frame, power on

ON

OFF

OFF

Carrier in receiving frame, unlocked position

ON

BLINK

OFF

Carrier in receiving frame, locked position

ON

(1)

ON

(1)

OFF

Drive activity active

BLINK

ON

OFF

Invalid Master/Slave jumper configuration on J5

BLINK

BLINK

BLINK

(1)

Indicators A and B will alternately blink during the 10 second drive spin down/up period after the key has been turned on or off.

When the carrier has been unlocked from the receiving frame, these lights will flash as the drive spins down. DO NOT REMOVE

THE CARRIER FROM THE RECEIVING FRAME DURING THIS PERIOD to prevent possible drive damage.

Receiving Frame Front Panel

(Figure 3)

•

The Key Lock/Drive Power Switch performs three (3) functions. The key lock

assures proper seating of the device carrier within the receiving frame, turns power

to the device carrier on and off, and prevents unauthorized removal or installation

of the carrier. For the computer to access data on the DE90i-A100 drive, the key

must be turned counterclockwise to the locked position.

The key can be attached (optional) to the locking mechanism as shown in Appendix

B.

•

Front Panel Indicator LEDs (Figure 3) Indicator LEDs on the DE90i-A100 receiving

frame front panel provide important operating information based on the following

conditions: