16

Appendix A - Specifications/Dimensions

StorCase Technology, Inc.

DE75i-SWC160 User's Guide - Rev. B01

SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI)

Standard set by the American National Standards Institute (ANSI). The following
DE75i-SWC160 specifications and dimensions are provided for reference only.

Environmental Specifications

Operating

Storage

Ambient Temperature

-5° C to 60° C

-25° C to 75° C

Relative Humidity

(1)

10% to 80%

10% to 90%

Altitude

-1000 to 50,000 ft

-1000 to 50,000 ft

-304m to 15240m

-304m to 15240m

Shock

(2)

10g

60g

(1)

Non-condensing with maximum gradient of 10% per hour.

(2)

11 msec pulse width 1/2 sine wave.

Physical
Specifications

Carrier

Receiving Frame

Height

1.08" (27.4mm)

1.13" (28.7mm)

(1)

Width4.67" (118.6mm)

5.75" (146.1mm)

Depth6.06" (153.9mm)

6.50" (165.1mm)

Weight

0.75lb (0.34kg)

0.95lb (0.43kg)

(2)

Chassis Reliability/Maintainability
MTBF

500,000 Hours

MTTR

5 Minutes

Preventive
Maintenance

None

Electrical Specifications
Input

+5V

55mA

+12V

13µA

(1)

With adapter bezel removed.

(2)

With carrier removed.