Appendix a - specifications/dimensions – StorCase Technology DE75i-SWC160 User Manual
Page 23

16
Appendix A - Specifications/Dimensions
StorCase Technology, Inc.
DE75i-SWC160 User's Guide - Rev. B01
SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI)
Standard set by the American National Standards Institute (ANSI). The following
DE75i-SWC160 specifications and dimensions are provided for reference only.
Environmental Specifications
Operating
Storage
Ambient Temperature
-5° C to 60° C
-25° C to 75° C
Relative Humidity
(1)
10% to 80%
10% to 90%
Altitude
-1000 to 50,000 ft
-1000 to 50,000 ft
-304m to 15240m
-304m to 15240m
Shock
(2)
10g
60g
(1)
Non-condensing with maximum gradient of 10% per hour.
(2)
11 msec pulse width 1/2 sine wave.
Physical
Specifications
Carrier
Receiving Frame
Height
1.08" (27.4mm)
1.13" (28.7mm)
(1)
Width4.67" (118.6mm)
5.75" (146.1mm)
Depth6.06" (153.9mm)
6.50" (165.1mm)
Weight
0.75lb (0.34kg)
0.95lb (0.43kg)
(2)
Chassis Reliability/Maintainability
MTBF
500,000 Hours
MTTR
5 Minutes
Preventive
Maintenance
None
Electrical Specifications
Input
+5V
55mA
+12V
13µA
(1)
With adapter bezel removed.
(2)
With carrier removed.
Appendix A - Specifications/Dimensions