beautypg.com

Southbend SX-55GC User Manual

Page 6

background image

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,

MODELS RG24-5, SX-34GC, SX-55GC

MANUAL 1195732 REV0 (11/22/2011) 6 HEAVY DUTY STEAM

2.0 INSTALLATION

GENERAL

Installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54

, or the Natural Gas and Propane Installation Code,

CSA B149.1

, as applicable.

1. The appliance and its individual shut off valve must be disconnected from the gas

supply piping system during any pressure testing of that system at pressures in

excess of ½ psi (3.5 kPa).

2. The appliance must be isolated from the gas supply piping system by closing its

individual manual shut off valve during any pressure testing of the gas supply

piping system at test pressures equal to or less than ½ psi (3.5 kPa).

Electrical grounding must be provided in accordance with local codes, or in the absence of local

codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA

C22.2, as applicable.

Ventilation must be provided in accordance with local codes, or in the absence of local codes,

with ANSI/NFPA 96 Standard for Ventilation and Fire Protection of Commercial Cooking
Operations.

WARNING: Electrical grounding instructions - units equipped with a

three-prong (grounding) plug for your protection against shock

hazard and should be plugged directly into a properly grounded

three-prong receptacle. Do not cut or remove the grounding prong

from this plug. (120 volt units only).

WIRING DIAGRAM FOR APPLIANCE IS LOCATED ON RIGHT HAND SIDE PANEL OF THE

COOKER CABINET.

NOTICE: If this equipment is being installed at over 2,000 feet altitude and was not so

specified on order, contact service department. Failure to install with proper orifice

sizing may void the warranty.

This manual is related to the following products: