Southbend 4601DD-2RR User Manual
Page 10
U
LTIMATE
R
ESTAURANT
R
ANGES
OWNER’S MANUAL 1190820 REV 4 (10/14)
PAGE 10
OF 34
S
TEP
3
:
A
TTACH
F
LUE
R
ISER AND
S
HELF
A
SSEMBLY
Place the flue riser assembly on the range as shown on the appropriate diagram below.
1. Slide the flue riser assembly over the bayonets until it bottoms out, as shown below.
2. Secure ends of flue riser assembly with two (2) 1/4-20 x 3/4 hex head bolts, flat washers and lockwashers.
3. Attach the shelf assembly (if ordered) to the flue riser assembly with 1/4-20 x 3/4 hex head bolts, flat washers and
lockwashers.
Figure 5
I
NSTALLATION
Installation of Flue Riser and Shelf Assembly
Single-Oven Models
Dual-Oven Models
S
TEP
4
:
E
LECTRICAL
C
ONNECTION
Wiring diagrams are located on the rear of the range. Be sure that the input voltage and phase match the requirements
shown on the serial plate (see Figure 1).
Ranges are factory-equipped either with a power cord or with one or two two-pole terminal blocks (one for each oven),
located behind cover plate(s) located on the rear of the range. To connect the supply wires, remove the appropriate cover
plate. Route the supply wires and the grounding wire through the strain relief fitting to the terminal block. Insert the supply
wires, one each, into the two poles of the terminal block and tighten the screws. Insert the ground wire into the grounding
lug and tighten the screw. Re-attach the cover plate.
Three phase ranges are wired as above, using only two supply wires. The third wire is not used and must be properly
terminated.
All ranges are shipped wired as specified by factory order. Conversion between single-phase and three-phase can
be accomplished by referring to phase loading and line amperes chart on wiring diagram for wire size and ampere
requirements.
S
TEP
5
:
G
AS
C
ONNECTION
If this equipment is being installed at over 610 meters altitude and that information was not specified when ordered,
contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure to
install with proper orifice sizing will result in poor performance and may void the warranty.