SERIAL “C”

Read and understand "Safety Instructions For Air Tools" and these instructions before oper-

ating this tool.

AIR SUPPLY

The efficiency of the tool is dependent on the proper supply of clean dry air at 90 psig (6.2 bar). The use of a line filter, pressure
regulator, and lubricator will insure maximum output and life of tools. Before connecting tool, blow out the air line to remove water
and dirt which may have accumulated.

HOSE AND HOSE CONNECTIONS

Supply hose should be not less than 3/8" (10 mm) I.D. Extension hoses should be at least 3/8" (10 mm) I.D. Use couplings and
fittings with at least 3/8" (10mm) I.D.

LUBRICATION

Use SIOUX No. 288 air motor oil. An airline lubricator, set to deliver 2 to 4 drops per minute, is recommended. If a lubricator is
not used, add .04 oz. (1.2cc, 12 to 15 drops) of oil into the air inlet twice daily.

Lubricate the gearing every 100 hours of operation with SIOUX No. 1198 grease.

GENERAL OPERATION

This tool is used to install skin clamps that temporarily hold components together. Skin clamps are often called by other names,
such as “Cleco clamps”, “Kwick-Loc”, “Wedgelok”, and sheet metal holders. To install skin clamps, place the nose piece of the
tool over the outer body of skin clamp. Engage the tool driver on the threaded 1/4" (6.4 mm) nut of the skin clamp. Pull the trigger
and run the tool until it stalls. To remove the skin clamp, follow the above procedure, but reverse the rotation of the tool.

Motor speed may be controlled by adjusting the slotted head screw on the top rear of the tool.

Form ZCE649
Date 2003July28/D
Page 1 of 12

*Sound Pressure

*Sound Power

*Vibration

Catalog No.

dBA

dBA

m/s

2

2S2300SR

73.18

84.7

Less Than 2.5

2SY2300SR

73.18

84.7

Less Than 2.5

*per PN8NTC1

*per PN8NTC1

*per ISO 8662

SOUND AND VIBRATION READINGS

DECLARATION OF CONFORMITY

We, Sioux Tools Inc., 250 Snap-on Drive, P.O. Box 1596, Murphy, NC, 28906, USA, declare under our sole responsibility that the products

2S2300SR, 2SY2300SR

to which this declaration relates are in conformity with the following standard or standards or other normative document or documents:

EN 792 (draft), EN 292 Parts 1&2, ISO 8662, Pneurop PN8NTC1

following the provisions of

89/392/EEC as amended by 91/368/EEC & 93/44/EC Directives.

July 1, 2003

Murphy, North Carolina, USA

Date and place of issues

Gerald E. Seebeck

President

Sioux Tools Inc.

Name and position of issuer

Signature of issuer