Product identification, Safety information – Desa CGEFP33PRB User Manual
Page 4

www.desatech.com
111245-01C
4
SAFETy INFORMATION
Continued
PRODUCT
IDENTIFICATION
Log Set
Wall Switch
Assembly
Piezo
Ignitor
Remote
Control
Manual
Override
Handle
Manual Ignition
Bypass Switch
Figure 1 - Fireplace Floor Assembly
Figure 2 - Fireplace
Top Louver Assembly
Firebox
Hood
Bottom Louver
Assembly
Screen
Assembly
Top Outer
Casing
Firebox
Support
Blower Assembly
(Optional)
4. This fireplace shall not be installed in a bed-
room or bathroom.
5. Do not use this fireplace as a wood-burning
fireplace. Use only the logs provided with the
fireplace.
6. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting. Do not
add lava rock around base. Rock and debris
could fall into the control area of fireplace.
7. To prevent the creation of soot, follow the instruc-
tions in Cleaning and Maintenance, page 29.
8. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
9. This fireplace needs fresh air ventilation to run
properly. This fireplace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS shuts down the fireplace if not enough
fresh air is available. See Air for Combustion
and Ventilation, page 6. If fireplace keeps
shutting off, see Troubleshooting, page 30.
10. Do not run fireplace
• where flammable liquids or vapors are used
or stored
• under dusty conditions
11. Do not use this fireplace to cook food or burn
paper or other objects.
12. Do not use fireplace if any part has been exposed
to or under water. Immediately call a qualified
service technician to inspect the fireplace and to
replace any part of the control system and any
gas control which has been under water.
13. Do not operate fireplace if any log is broken.
Do not operate fireplace if a log is chipped
(dime-sized or larger).
14. Turn fireplace off and let cool before servicing.
Only a qualified service person should service
and repair fireplace.
15. Operating fireplace above elevations of 4,500
feet could cause pilot outage.
16. To prevent performance problems with pro-
pane/LP units, do not use propane/LP fuel
tanks of less than 100 lb. capacity.
17. Provide adequate clearances around air
openings.