Calibrating the temperature display

1. Switch off the DIGIMON
2. Plug in the thermocouples (K-type).

Room and measurement temperatures must remain constant at 77°F +/-7°F
and be stable for at least 20 minutes. The thermocouple cables must be
straight (unwound).

During calibration, you should neither touch the cables nor the plugs.

3. Hold down the

button and switch on the device using the

button.

The display shows "Password" 000

4. Press the

/

button to select code 018.

5. Press the

button to exit.

Display shows “T-call”

6. Press the

button and then the

button to calibrate.

7. During calibration, ensure that both thermocouples are connected to the

DIGIMON.

The display shows

(low pressure side)






The current temperature displayed on the DIGIMON should not deviate

by more than +/-0.5°C from the room temperature.

8. Press the

button to confirm.

The display shows:







SET

SET

R

-

SET

R

-

R

+

ON/OFF

LIGHT

LP

00xxx

27.0°C

Temperature code

Current temperature

LP

End

00xxx

27.0°C