beautypg.com

Model 3vh19, 3vh19, Theory of operation – Dayton 3VH19 User Manual

Page 3: Product identification specifications

background image

Version B - For Reduction

G016.J

®

3

Model 3VH19

Dayton Operating Instructions and Parts Manual

3VH19

Maximum Supply

Minimum Supply

Pressure to Regulator

Pressure to Regulator

1/2 PSI

6" w.c.

Theory of Operation

THE FUEL SYSTEM

The gas supply attaches to the heater by a
minimum 3/4 inch i.d. hose or flexible
connector. User must supply hose or
flexible connector. The length should be
no more than 10 feet long. The natural
gas moves through the regulator and out
the nozzle.

THE IGNITION SYSTEM

The piezo ignitor lights the pilot fuel
supply.

THE AUTOMATIC CONTROL SYSTEM

The automatic control valve shuts off the
heater if the flame goes out.

Figure 2 - Product Identification

Product Identification

Specifications

Output

Fuel

Size

Weight

Model

Rating Btu/Hr

Fuel

Consumption

LxWxH(Inches)

(pounds)

Manifold Pressure

3VH19

100,000

Natural

100 Cubic Feet/Hour

16 x 16 x 29.5

23 (Heater)

4" w.c.

Gas Only

27 (Shipping)

Ignitor
Electrode

Pilot Burner

Regulator

Automatic Control
Valve Button

Base
Assembly

Top

Main
Burner
Tube

Nozzle

Emitter

Shell

Piezo Ignitor
Button

Valve
Inlet

Thermocouple