Model 3vh19, 3vh19, Theory of operation – Dayton 3VH19 User Manual
Page 3: Product identification specifications
Version B - For Reduction
G016.J
®
3
Model 3VH19
Dayton Operating Instructions and Parts Manual
3VH19
Maximum Supply
Minimum Supply
Pressure to Regulator
Pressure to Regulator
1/2 PSI
6" w.c.
Theory of Operation
THE FUEL SYSTEM
The gas supply attaches to the heater by a
minimum 3/4 inch i.d. hose or flexible
connector. User must supply hose or
flexible connector. The length should be
no more than 10 feet long. The natural
gas moves through the regulator and out
the nozzle.
THE IGNITION SYSTEM
The piezo ignitor lights the pilot fuel
supply.
THE AUTOMATIC CONTROL SYSTEM
The automatic control valve shuts off the
heater if the flame goes out.
Figure 2 - Product Identification
Product Identification
Specifications
Output
Fuel
Size
Weight
Model
Rating Btu/Hr
Fuel
Consumption
LxWxH(Inches)
(pounds)
Manifold Pressure
3VH19
100,000
Natural
100 Cubic Feet/Hour
16 x 16 x 29.5
23 (Heater)
4" w.c.
Gas Only
27 (Shipping)
Ignitor
Electrode
Pilot Burner
Regulator
Automatic Control
Valve Button
Base
Assembly
Top
Main
Burner
Tube
Nozzle
Emitter
Shell
Piezo Ignitor
Button
Valve
Inlet
Thermocouple