beautypg.com

Troubleshooting guide – Dakota Digital 3 User Manual

Page 27

background image

MAN 650066:E

27

TROUBLESHOOTING GUIDE

This is a list of some problems and their solutions which may be encountered when installing your
instrumentation system. If you cannot determine what the problem is or how to solve it, please call our
technical assistance line (605) 332-6513 or email [email protected].

* A note on vehicle grounding. *

The most common cause of problems with electric gauges and other sensitive vehicle electronics

is poor ground connections. The engine block has the highest ground currents of any point in the
vehicle. The ignition system, electric gauge senders, starter, alternator, etc. all use the engine block for
a ground point. Since the alternator is grounded directly to the engine block, all ground currents in the
entire vehicle must pass through the engine block while the engine is running. A weak or loose
connection can cause many unexpected problems that may be difficult to track down. The engine block
should have heavy ground straps to both the chassis and the body. The main negative cable from
the battery should be connected directly to the engine block

.


Symptom

Possible

Problem

Solution

-----------------------------------------------------------------------------------------------------------------------------------
System does not light up

Control box may not be getting

Check if the control box has

and LED off.

power.

12 volts connected to it.

Control box may not be getting

Check if the control box has

a ground.

a proper ground connection.

Do

not

use

a

battery

charger

to

power

the

system.

The

control

box

may

have

Contact

Dakota

Digital’s

service

an internal problem

department with a description of

the problem.


System does not light up

Control box may be getting too

Check if power to control box is

and LED is on steady.

low of a voltage.

at least 11 volts.

Do

not

use

a

battery

charger

to

power

the

system.


System does not light up

The display system may not be

Check the ribbon connector on the

and LED is flashing.

getting power.

display system wiring harness

Be

sure

the

pins

and

stripe

are

aligned

with control box markings.

Check

the

display

system

wiring

harness

for

broken

or

cut

wires.


One display does not

The corner of the display is white

Return the display panel to

light up at all, all others

or the display is cracked

Dakota Digital for repair. Include

work correctly.

or broken.

a phone number and address.

Call

for

RMA

#

before

returning.


The tachometer will not

The control box is not connected

Make sure the control box is

show a reading.

to the engine properly

connected to your particular

ignition

system

properly.

The tachometer signal wire is

Check the connections at both

loose or broken.

ends of the wire.

The engine cylinder setting is

Refer to the tach setup section

incorrect.

of

the

installation

manual.

The tach signal setting is

Refer to the tach setup section

incorrect.

of

the

installation

manual.