beautypg.com

Dakota Digital 3 User Manual

Page 20

background image

MAN 650066:E

20

Display update setup (

UPDATE)

The display update rate can be adjusted so the reading on the tachometer doesn’t

change so quickly. This is a personal preference and is used to “slow” the reading by
averaging. The value can be changed from

slow, mid, or fast.

• When

“UPDATE” is displayed, press and hold SW1 until you get “ - ”.

• Release SW1 and the current update rate will be displayed.

• Press and release SW1 to increase the value from “SLOw” “ MID” “ FAST”.

• When the desired setting is displayed, press and hold SW1 until “ - ” “DONE” is displayed.

• Release the switch to go onto the next sub-menu item.

RPM warning setup (

WARN)

This is used for the turn on point for the WARN output on the control box. When the

RPM reading is above this setting, the output will activate, providing a ground signal. It can be
used to turn on a shift light or other RPM based devices. The value is adjustable from 2200
RPM – 14800 RPM in 100 RPM increments.
• When

“WARN” is displayed press and hold SW1 until you get “ - ”.

• Release SW1 and the current warning point will be displayed.

• Press and release SW1 to increase the value from “W 2200” – “W14800”.

• When the desired setting is displayed press and hold SW1 until “ - ” “DONE” is displayed.

• Release the switch to go onto the next sub-menu item.

Tach signal setup (

SIGNAL)

This menu will allow you to select from two different tach-input types. A low voltage, “5

LO”, tach signal or a high voltage tach signal, “12 HI”. A low voltage signal is usually one
picked up from the ECM. Low voltage may also be considered a 0-5V square wave. If you are
getting the tach signal from the ignition coil or points, set this for the high voltage signal“12 HI”.
To pick up a tach signal from a traditional coil wire the tach input to the negative side of the coil.
• When

“signal” is displayed press and hold SW1 until you get “ - ”.

• Release SW1 and the current value will be displayed.

• Press and release SW1 to toggle from “12 HI” to “5 LO”.

• When the desired setting is displayed, press and hold SW1 until “ - ” “DONE” is displayed.

• Release the switch to go onto the next sub-menu item.

Exit tach setup (

done)

This will allow you to exit the tach setup and go on to the next setup menu.

• When

“Set done” is displayed, press and hold SW1 until you get “ - DONE ”.

• Release the switch to go onto the next menu.

VOLT SETUP

The Volt setup allows you set a warning point that will cause the Volt display to flash

whenever the voltage drops below the warning value. The low voltage point can be set from 10
-13.1 volts.
• Press and hold SW1 while turning the key on.

• Release the switch and then press and release SW1 to get to the “volt” setup menu.

• When

“volt” is displayed press and hold SW1 until you get “ - ”, release SW1 and “WARN”

will be displayed.

• When

“WARN” is displayed press and hold SW1 until you get “ - ”.

• Release SW1 and the current warning point will be displayed.

• Press and release SW1 to increase the value from “LO 10.0” – “LO 13.1”.

• When the desired setting is displayed, press and hold SW1 until “ - ” “DONE” is displayed.