Connecting Additional Safety Devices

The Mighty Mule® 500 is equipped with built-in obstruction sensitivity. The opener is designed to stop and reverse the
gate within 2 seconds when it comes in contact with an obstruction. However, obstruction sensitivity, although functioning
properly, may not be sensitive enough to prevent bodily injury in some circumstances. To augment your protection against
entrapment, GTO recommends using some form of additional safety device. When installed, contact sensors must be
mounted in compliance with UL 325, Underwriters Laboratories safety standard for gate openers. Review page 5 for infor-
mation about mounting requirements for safety edges ("contact sensors").

Refer to the sensor manufacturer’s instructions for
information about installing these devices on a vehicular
gate.

PLEASE NOTE: Contact sensors are not included with the Mighty Mule® 500.

The Mighty Mule® 500 will ONLY accept accessory devices with normally open dry contact output.

Make sure the power switch to the opener is

turned off before connecting safety device

wiring to the terminal blocks. Unplugging the

transformer does not turn power to the opener

OFF.

Contact Sensor Input Connection:

Connect one of the OPEN EDGE contact sensor wires to the
COMMON (COM) terminal and the other to the OPEN
EDGE
terminal on the Mighty Mule® 500 control board.

Connect one of the CLOSE EDGE contact sensor wires to the
COMMON (COM) terminal and the other to the CLOSE
EDGE
terminal on the Mighty Mule® 500 control board.

Activation of a contact sensor while the gate is in motion
will cause the gate to stop and reverse within two (2)
seconds.

Contact Sensors (safety edges)

If not installing a contact sensor skip to next section.

Although GTO strongly recommends the use of additional safety devices, we do not endorse any

specific brand names. Only use products that are certified and listed to be in compliance with

any applicable UL standards (United Laboratories) and national and regional safety codes.

Call GTO Sales at 1-800-543-4283 for information on compatible

products for your specific application.

Wire from Contact Sensor

(open safety edge)

Wire from Contact Sensor

(close safety edge)

RECEIVER

COM COM

CY

CLE

CL

OSE

SAFETY

EXIT/ OPEN

SHADOW LOOP

CL

OSE

EDGE

OPEN EDGE

BLK

GRN

RED

STALL FORCE

MI

N

MA

X