For troubleshooting, functional validation or system Reset, you will need to open
the XAP-1040. To do so, remove the 4 screws at the back of the unit. After doing so,
carefully lift the base up and to the right as demonstrated below:
View of XAP-1040 Opened
CAUTION: Before removing the cover and/or attempting to service
the XAP-1040, be sure to unplug all cables and dismount the device.
Use caution to see that no external elements are introduced inside the
enclosure and that reasonable precautions are taken to minimize static
and electromagnetic contamination of the electronic components. Avoid
touching any of the internal electronics, except in the case of a Reset.
CAUTION: When lifting the base, be careful not to pull, bend or
otherwise move the base or cover excessively. By simply
lifting the base slightly, you should be able to see the LEDs
as well as access the Reset button. When re-assembling the
unit, be sure to maintain the weather-resistant integrity of
the enclosure by verifying that the rubber seal is properly
seated and the four screws are fi rmly in place, but not
over-tightened.
With the base lifted to the right, System LEDs and the Reset button can be seen as
shown here: