Specifications – Lamar Technologies Alpha C-25 User Manual
Page 19

6. SPECIFICATIONS
ALPHA C-25 Manual V2.1.doc
Page 19
6. SPECIFICATIONS
AC Line Input:
120 volts ± 5%, 50/60Hz, 13 amperes or
230 volts ± 5%, 50/60Hz, 6 amperes
(selectable on rear of unit) NOTE: Unit will
operate ± 10% but with lower max amp
ratings at -10%.
Constant Current
Mode:
Capacity
Accuracy
Approx. 37 volt limit non-adjustable. 0-7 to 8
amps at 37 volts.
< ± 3% from charge initiation to completion
Constant Potential
Mode
Setting
Selectable 14.3/28.5 volts; 25 ampere limit.
Adjustable.
Accuracy
< ± 0.2 volts
Timer
Setting
Adjustable from 0 to 999.9 minutes
Units
Selectable on front of timer from 0.1 to 999.9
minutes
Accuracy
< ± 0.1%
Digital
Meter Accuracy:
Voltmeter
< ± 0.3 volts
Ammeter
< ± 0.3 amperes
Cooling:
Fan cooled
Housing:
Aluminum chassis
Outer Dimensions: Height
14 in. (356 mm)
Depth
15 in. (381 mm)
Width
5 3/4 in. (146 mm)
AC Line Cord:
AWG 14 3 wire grounded 6 ft long with 120
volt 15 ampere plug. User required to change
to 230 volt plug if needed.
DC Discharge
Cable:
Two 4 ft long, terminated in ring terminals
(Aircraft Battery Connector Optional)
Weight:
Net weight 45 lbs (20.4 kg).
Fuses:
AC line fuse
20A/250V, type MDA 1 1/4 x 1/4
DC line fuses
Two 35A/32V, type AGC 1 1/4 x 1/4
Modes:
1) Constant Current mode without voltage
limit
2) Constant Potential mode for 12 volt and
24 volt batteries.