OPERATING HEATER

Continued

HAND-HELD REMOTE

CONTROL OPERATION

1. Slide selector switch on remote receiver to

the REMOTE position.

2. Slightly pull and turn auxiliary knob so the

AUX is to the left and right and ON is to the

top and bottom positions.

3. Light the pilot. Follow steps 1 through 6

under Lighting Instructions, page 13.

DISPLAY

The LCD display on the remote control indi-

cates current room temperature in Fahrenheit

or Celsius. The small flame indicates burner/

valve in operation. ROOM indicates remote

is in thermo operation. TEMP appears during

manual operation. SET appears during the

time of setting the desired temperature in the

thermostatic operation.

Turns
heater
ON

Turns
heater
OFF

Changes heater
from Manual
Mode to
Thermostatic
Mode

Sets
temperature in
Thermostatic
Mode

Figure 19 - Hand-Held Remote Control Unit

SETTING FAHRENHEIT AND CELSIUS SCALE

The factory setting for temperature is Fahr-

enheit. To change this setting to Celsius, press

the ON and OFF buttons on remote at the same

time. Follow the same procedure to change from

Celsius back to Fahrenheit.
MANUAL FUNCTION
On Operation

When the ON button is pressed the appliance

flame will come on. The LCD screen will show

ON for three seconds, then default to room

temperature and the word TEMP and flame

icon will show.
Off Operation

When the OFF button is pressed the appliance

flame will shut off. The LCD screen will show

OF for three seconds, then default to room tem-

perature and the word TEMP will show.

9. With the auxiliary knob in the AUX posi-

tion, push the ON button on the remote

control. To adjust the temperature with the

remote control, follow the instructions on

page 15. When the temperature surround-

ing the remote control drops below the set

temperature, the burner should light. The

remote receiver behind the unit must be in

the REMOTE position.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Press in and turn pilot knob clockwise

to the OFF position.

2. Unplug any electrical power to the appli-

ance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

If auxiliary knob is in AUX position, push OFF

button on remote control.

If auxiliary knob is in ON position, turn pilot

knob clockwise

to the PILOT position.

THERMOSTAT

OPERATION

The thermostat used on this heater senses the

room temperature at the location of the hand-

held remote control. At times the room may

exceed the set temperature. If so, the burner will

shut off. The burner will cycle back on when

room temperature drops below the set tempera-

ture. All plaques will turn off and on.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions, page 13.

2. With pilot knob pressed in, strike match.

Hold match to pilot until pilot lights.

3. Keep pilot knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

pilot knob. Continue with step 8 under

Lighting Instructions, above.