Troubleshooting – Denso CLASSIC PLUS 14 User Manual
Page 23
17
Self-Diagnostic Codes
Self-Diagnostic Codes will be displayed on the Control Board under
the following conditions:
Code
Condition
dF
When the evaporator thermistor
disengages the compressor.
FL
When the drain tank switch shuts
off the unit (FULL TANK LED
flashes).
AS
When unit disengages the com-
pressor while the condensate
pump is discharging water.
HP
When the high pressure switch
disengages the compressor.
TROUBLESHOOTING
Check the following points before calling a qualified technician.
SYMPTOM
POSSIBLE CAUSE
REMEDY
Unit does not operate
➀
Ground fault breaker blown
Reset breaker
➁
Drain tank is full
Empty the drain tank
(FULL TANK LED will be
flashing)
Insufficient cooling
➀
Dirty/blocked air filters
Clean air filters
➁
Air inlet/outlet blocked
Clear air inlet/outlet
➂
Improper temperature setting
Set to desired position
If symptoms persist after the above actions have been taken, turn the
unit off, disconnect the power cord plug and contact your MovinCool
reseller.