7 subnet faults, 9 operation and configuration – Lab.gruppen NLB 60E NomadLink User Manual
Page 26

26 NLB 60E Operation Manual
For obvious reasons, faults will be indicated
only when they occur.
Entering “Device type” provides a list of all device 
model types:
Entering “Serial number” provides a list of all device 
serial numbers:
Entering “Firmware version” will provide a list of the 
current firmware versions of all devices:
Device: 1:1
Type: C 48:4
Device: 1:1
Ser#: 122222221
Device: 1:60
Ser#: 122222222
Device: 1:1
FW ver. 1.00
Device: 1:60
FW ver. 1.02
9.3.7 Subnet Faults
The Subnet Faults display shows the total number of 
faults found in the Subnet as a number in the lower 
left corner.
Press ENTER to display a list of the various faults.
If the number of faults is 0 and you press ENTER 
anyway, this will take you to a display saying: “All 
ok !”
When faults are indicated, press ENTER to scroll 
through the list of faults using the SELECT UP/
DOWN arrow buttons.
The fault list is dynamic: if a fault is corrected or disap-
pears (e.g. temperature drops below fault threshold) 
the display will switch over to the previous fault. “All 
OK !” will be displayed when no faults are present. 
General network faults are shown at the top, followed 
by device specific faults.
Communication errors on NomadLink are displayed 
as a percentage. 0% indicates no problems, 100% 
indicates no communication at all
In case of communication errors, check cable con-
nections and general system setup.
Subnet Faults
110 Enter
Subnet 1
Com.errors XX%
9 oPeRAtIon AnD conFIGURAtIon