Quick Start Tutorial
Lake LM Series Quick Start and Field Reference Guide Rev 1.2.8
26.
Tap any of the four magnifying glass icons on the right-side of Module A’s block diagram to open the
Output Configuration screen.
27.
Verify that the Output Configuration is routed as shown in Figure 6-1 below where Source = Module
Outputs and Destination = Analog Outputs.
Figure 6-1: Classic 3+1 Analog Output Configuration
28.
If the output assignments are not as shown, tap the Clear All Assignments button (split arrows);
tap YES to the warning dialog box; then tap the numeric buttons correctly route the audio to the
appropriate physical output/s.
29.
Tap the return key to close this screen and return to I/O CONFIG.
30.
The following settings on the left-side of the I/O CONFIG screen should be correct by default; if they
are incorrect, please refer to the Lake Controller Operation Manual for further details.
▸
PRIMARY DIGITAL CLOCK:
Internal – 96 kHz
▸
SRC CLOCK:
Internal – 88.2 kHz
▸
INPUT CONFIGURATION:
#1: Auto
Type: Analog
Offset/Headroom: 26 dBu
#2: Auto
Type: Analog
Offset/Headroom: 26 dBu
▸
DANTE CONFIGURATION:
Dante Disabled
▸
ANALOG ISO-FLOAT & AES TERMINATION:
Inputs 1-2: Floating
Outputs 1-6: Floating AES: Terminated