Self-Diagnostic Control System
AquaFit™, AquaFit™Dual Temp (Pool-Side), AquaPro™
Symptom
Problem
Corrective Action
Non-functional 
High Temperature Sensor: 
Open high temperature sensor. Heater is 
deactivated. 
 
Call your dealer for service.
Non-functional temperature sensor: 
 
Open temperature sensor. Heater is 
deactivated. 
Call your dealer for service.
Water Flow Problem: 
Pressure switch is not closed when the 
pump is activated. Heater is deactivated. 
Proper flow of water is inhibited or 
pressure switch has malfunctioned. Check 
for proper water level, ensure pump is 
primed and/or check for clogged filter. 
Pressure switch may need to be adjusted. 
 
Call the dealer for service.
Pressure switch problem: 
Pressure switch is closed, while pump is 
deactivated. Pressure switch may need to 
be adjusted.
 
 
 
Call your dealer for service.
Cool condition:
If the water temperature drops 20°F 
(11°C) below the set temperature, the low 
speed pump and the heater will activate to 
bring the temperature within 15°F (8°C) of 
the set temperature. 
 
 
 
No corrective action is required. 
Freeze condition:
A potential freeze condition has been 
detected (55°F / 12.8°C.)
No action is required.
The low speed pump will be activated along 
with the heater. The spa will automatically 
heat, until the spa is out of danger (65°F / 
18.3°C.) 