7
THE SURE-LOCK TRANSMITTER
(Figure 1-2)
1. OUTPUT FREQUENCIES: Frequencies are selectable combinations of 8.1
kHz, 81 kHz, and 480 kHz, according to model.
2.
on individual output jacks.
3. OUTPUT MODE: Conductive and/or inductive with automatic load match-
ing. Conductive mode compatible with live cables carrying up to 240 VAC,
50-60 hertz, according to model.
4. OUTPUT POWER: Variable 0.6 or 3 watts with automatic load matching.
Loads from 5 ohms to 10 K ohms.
5. LCD: Automatic backlighting. Indication of output power, frequency oper-
ating mode, self-test status, line voltage, load matching and battery level.
LCD not available on 81 kHz model.
6. OPERATOR INTERFACE: Two sealed overlay membrane switches on all
low frequency models. High frequency model uses one switch only.
7. ADDITIONAL CONNECTORS: Safety ground lug with wing-nut connects
chassis and top panel to ground to prevent electrical shock.
8. BATTERY TYPE: Sealed lead-acid, 6 VDC on low frequency models.
9. BATTERY LIFE: Depending on frequency and power level selection, life is
10 - 100 hours. An automatic shutdown time of 60 minutes with no switches
FREQUENCY buttons simultaneously until 8.1 is shown on the LCD will
turn off the Automatic Shutdown Feature.
10. BATTERY STATUS: Continuously indicated.
11. BATTERY CHARGER: 120 VAC, 50-60 hertz and as an optional accessory
operate while the 12 VDC charger is connected.
12. OPTIONAL ACCESSORIES: Includes coupler clamps, conductive attach-
ments, and a 12 VDC vehicle source charger.
13. TEMPERATURE RANGE (operational): -25 degrees Fahrenheit to 150
degrees Fahrenheit (-32 degrees Celsius to 65 degrees Celsius).