• BACLI

i. Press up button to turn on or to turn off the display backlight.

Fig. 3-5


Although the ppm-m readout will not be updating, the instrument will still operate
properly while in a menu option other than the run display.

Using the DMD Mode

The Digital Methane Detection (DMD) mode is a highly sophisticated detection
algorithm that greatly enhances the use of the RMLD-IS. In most situations, the operator
should survey with the DMD mode turned on. To turn on the DMD mode, press the
DMD button (the DMD icon will appear on the display). This mode can only be activated
while in the main survey screen.

Fig. 3-6: DMD icon is displayed when in DMD mode


While using the DMD, no sound will be heard until a detection of methane occurs. The
pitch of the sound will be relative to the methane concentration. The higher the pitch, the
stronger the methane concentration is.

A low-pulsating or continuous sound will indicate a warning due to an infrared laser low
light level condition or instrument fault. The warning icon will also be displayed
indicating that the light level is too low (See Long Range Scanning Pg. 24). The operator
needs to move in closer to get in range.

Should the warning persist, it could be due to a fault in the instrument. Check the error
code being displayed and follow the instructions in the troubleshooting guideline.

DMD icon is on

101296-0 RMLD IS MANUAL REV J