PRELIMINARY EXAMINATION

Remove the instrument from the packing material and examine it
to make sure that no damage has occurred during shipping. If there
is any damage, notify your Dealer.
The meter is supplied complete with:

HI 76407/4

DO probe with 4 m cable

• 2 spare membranes with O-rings

HI 7041S electrolyte solution (30 mL)

Calibration screwdriver

• Batteries (3 x 1.5V AAA)

• Instruction manual

• Rugged carrying case

Note: Save all packing material until you are sure that the

instrument functions correctly. All defective items must
be returned to us in the original packaging with the
supplied accessories.

GENERAL DESCRIPTION

HI 9142 is a rugged, waterproof meter that solves the common
problems of field use, such as cold, rain, snow and dust, that can
damage a meter, rapidly deteriorating its performance and life.
It is very simple to use: calibration is performed with

HI 7040 zero

oxygen solution, while 100% calibration is done in air.
The polarographic probe (

HI 76407/4)

is provided with a

membrane covering the sensors and a built-in thermistor for
temperature measurement and compensation. The thin permeable
membrane isolates the sensor elements from the testing solution,
but allows oxygen to enter. When a voltage is applied across the
sensor, oxygen that has passed through the membrane reacts
causing current to flow, allowing the determination of oxygen.

The probe included with the meter is supplied with a 4 m (13')
cable that allows measurements to be taken even in even hard to
reach places. For applications that require longer probe cables, the
HI 76407/10 and HI 76407/20 probes with a 10 m (33') or 20 m
(67') cable are available.

Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the
instrument.
This manual will provide you with all the necessary information
for correct use of the instrument, as well as a precise idea of its
versatility.
If you need additional technical information, do not hesitate to
e-mail us at [email protected] or view our worldwide contact
list at www.hannainst.com.

TABLE OF CONTENTS

PRELIMINARY EXAMINATION............................................... 3
GENERAL DESCRIPTION ...................................................... 3
PROBE FUNCTIONAL DESCRIPTION ...................................... 4
METER FUNCTIONAL DESCRIPTION ..................................... 5
SPECIFICATIONS ................................................................. 6
PROBE INITIAL PREPARATION ............................................. 7
CALIBRATION PROCEDURE .................................................. 9
TAKING MEASUREMENTS ................................................. 11
ALTITUDE AND SALINITY COMPENSATION .......................... 12
PROBE AND MEMBRANE MAINTENANCE ............................ 14
BATTERY REPLACEMENT ................................................... 16
ACCESSORIES ................................................................... 17
WARRANTY ...................................................................... 18