INTERFERENCES
Interference may be caused by air bubbles or turbidity in the sample. Scratched or dirty cuvettes
will also affect readings. Always check clearness of cuvettes prior to use.

BATTERY MANAGEMENT

To save battery, the instrument shuts down after 10 minutes of non-use in

measurement mode

and after 1 hour of non-use in

calibration mode.

If a valid measurement was displayed before auto
shut off, the value is displayed when the instrument
is switched on. The blinking

“CAL” means that a

new calibration has to be performed.

One fresh battery lasts for around 750 measurements, depending on the light level.
The remaining battery capacity is evaluated at the instrument startup and after each measurement.
The instrument displays a battery indicator with three levels as follows:
• 3 lines for 100 % capacity
• 2 lines for 66 % capacity
• 1 line for 33 % capacity
• Battery icon blinking if the capacity is under 10 %.
If the battery is empty and accurate measurements can’t be taken anymore, the instrument
shows “dead batt

dead batt

dead batt

dead batt

dead batt” and turns off.

To restart the instrument, the battery must be replaced with a fresh one.

Recommendations for Users
Before using these products, make sure that they are entirely suitable for your specific application and for the environment in
which they are used.
Operation of these instruments may cause unacceptable interferences to other electronic equipments, this requiring the operator
to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance.
To avoid damages or burns, do not put the instrument in microwave oven. For yours and the instrument safety do not use or
store the instrument in hazardous environments.

HI 96760 is warranted for two years against defects in workmanship and materials when used
for its intended purpose and maintained according to the instructions.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact your dealer. If under warranty, report the model number, date of
purchase, serial number and the nature of the failure. If the repair is not covered by the warranty,
you will be notified of the charges incurred.
If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization
Number from the Customer Service Department and then send it with shipment costs prepaid.
When shipping any instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card within 14 days from the
date of purchase.

Hanna Instruments reserves the right to modify the design, construction and appearance of its
products without advance notice.

• Turn the instrument off by pressing

MARCHE/ARRET.

• Turn the instrument upside down and remove the battery cover by turning it counterclockwise.

• Extract the battery from its location and replace it with a fresh one.
• Insert back the battery cover and turn it clockwise to close.

To replace the instrument’s battery, follow the steps:

ACCESORIES

ANAL

ANAL

ANAL

ANAL

ANALYSIS KIT

YSIS KIT

YSIS KIT

YSIS KIT

YSIS KIT

HI93703-56

Kit for Maple Syrup analysis, including 82 cuvettes, 30 mL of

Glycerol

and two 5 mL Syringe (75 tests average)

OTHER ACCESORIES

OTHER ACCESORIES

OTHER ACCESORIES

OTHER ACCESORIES

OTHER ACCESORIES
HI 721310

9V battery (10 pcs.)

HI 731318

Cloth for wiping cuvettes (4 pcs.)

HI 731335

Caps for cuvettes

HI 741218

Carrying case

BATTERY REPLACEMENT

WARRANTY