Model vs2 – Hall Research VS-2 User Manual
Page 8
MODEL VS2
6
When you turn the unit on a menu similar to below appears:
Version 1.2
Copyright 2006
----------------------
M E N U
----------------------
1 = #1 Input
2 = #2 Input
a = Auto mode
b = Blank
u = Un-blank
----------------------
Control Codes (1 byte commands from external control device)
ASCII 1 (or Hex31)
Selects input #1 (immediately and unconditionally). The device
will respond with:
In #1 Selected
If the previously displayed output was input #2, then prior to
switching the unit will blank the output for a period of
approximately 25 milliseconds, switch to input #1 and un-blank
the output. This is done in order to reduce or eliminate the
undesired “flash of junk” on screen when the monitor is re-
synchronizing from one input to the other. Most monitors and
LCD’s do take some additional time to re-sync to the new input
and so the blanking may appear to be longer than 25 Ms. The
reason for the initial blanking during the switching is to prevent
a jittery screen that may appear for a fraction of a second due to
initial switching.