Connection diagram, Dip switch settings – Hall Research VS-2 User Manual
Page 5
3
COMPACT ELECTRONIC VGA SWITCH
Connection
Diagram
Dip Switch Settings
The Model VS-2 provides a convenient dip switch for setting the desired mode of
operation. It is recommended to set the jumper prior to applying power to the unit,
however the device does monitor the dip switch settings when on and changes mode of
operation as needed.
Normal:
(All up)
This is the default mode setting for the switch. In this mode the unit is controlled from the
push-button switch cord. The switch at the end of the cable is momentary and it has a
built-in LED. The LED is used to indicate which input is selected. Solid on means Input 1,
blinking means Input 2 (when blanking mode is enabled, LED off means blanked output).
Every time you press the button the output switches from the current input to the other
input. When blank mode is on, double clicking the button will blank the output screen.
VS-2
Pushbutton
Switch Cord
- OR -
RS-232 Device
- OR -
TTL Level
- OR -
Automatic