Model HR-1P Projector Controller

SPECIAL CONNECTION INFORMATION

:

• By default the HR-1P is configured to detect a

CONTACT or a NON-ISOLATED VOLTAGE. By

special request at the time of the order, the unit can
be configured to detect an OPTICALLY ISOLATED
VOLTAGE.

• Both the CONTACT/NON-ISOLATED and

OPTICALLY ISOLATED configurations use the EXT

CTL jack for detection of the signal.

For Contact/Non-Isolated Voltage

configurations of the unit, ALWAYS ensure that if
you supply a voltage to the EXT-CTL jack, it is applied
as CENTER POSITIVE in the range of 3-24 vDC. The
device will not sense 0 volts by unplugging the EXT

CTL jack. The sensing circuit is normally ‘pulled’ high.
This means that in order to detect the ‘No-Voltage
applied’ condition, your circuit must represent a low
resistance.

For OPTICALLY ISOLATED configurations,

ALWAYS ensure that the voltage is applied as a
CENTER POSITIVE in the range of 3-9 vDC. This
voltage should be isolated from the units Supply
Voltage.

• Failure to observe these warnings may result in

damage to the unit and void your warranty