beautypg.com

Uvb1-cp user's manual 4 5.0 troubleshooting, 1 contacting hall research and shipping/packaging, 0 specifications – Hall Research UVB1-CP-S User Manual

Page 4

background image

UVB1-CP User's Manual

4

5.0 Troubleshooting

Most common problems are caused by the following:

• You have confused the Sender and the Receiver

• You have mismatched the RGB colors on the cable connections to

the box and equipment

• You are using a Cat5 cable that is too long or is not straight

through

• You have not connected the power supply, or it is not powered

• Your Monitor does not support the resolution that you are sending

it (in which case you should check operation without the Balun first)

5.1 Contacting Hall Research and Shipping/Packaging

Contact the Hall Research Technical Support Department at 714-641-
6607 or via email or web. Before you do, make a record of the history of the
problem. We will be able to provide more efficient and accurate assistance
if you have a complete description. If you need to ship your converter for
repair, make sure to get a Return Material Authorization (RMA) number
first.


6.0 Specifications

Standards

Analog Component Video YPbPr or RGB signals with
sync-on-green.

Resolutions

All Standard TV and HDTV from 480i to 1080p

Video Level

1.0 volt p-p on Y and 0.7 v p-p on Pb and Pr

Bandwidth

20 Hz to 450 MHz

Common Mode
Noise Rejection

100 dB @ 60 Hz, 70 dB @ 1 MHz, 50 db @ 10 MHz

Max Distance

Up to 1000 ft. (305 meters) - See table 4.1 for details

Temperature

Operating: 32 to 122 Deg F (0 to 50 Deg C);

Storage: -40 to +185 Deg F (-40 to +85 Deg C)

Enclosure

Black Plastic ABS-94VO, UL File#56070

MTBF

100,000 hours (calculated estimate)

Power

Via the included power adapter. Voltage: 9v DC Center-
Positive. Average Power Consumption: 850 milliwatts

Size (H x W x D)

1.1” H x 2.6” W x 2.6” D Each Device